File size: 199.7KB
CM10 Series Technical Parameters
Model |
CM10F |
CM10FH |
CM10N |
CM10FN |
|
Working Principle |
Magnetic Induction |
Magnetic Induction |
Eddy Current |
Magnetic Eddy Current Integrated |
|
Measurement Range (um) |
0-3000 |
0-10000 |
0-2000 |
0-1500 |
|
Lower Limit Resolution (um) |
0.1 |
0.1 |
0.1 |
0.1 |
|
Accuracy Error (um) |
±(2%H+2) |
±(2%H+10) |
±(2%H+2) |
±(2%H+2) |
|
Testing Conditions (mm) |
Minimum Curvature Radius |
5 |
10 |
5 |
5 |
Minimum Area Diameter |
20 |
40 |
20 |
20 |
|
Matrix Critical Thickness |
0.5 |
2 |
0.5 |
0.5 |
|
Display |
High Contrast Segment Code LCD Screen (LED Backlight) |
||||
Statistical Function |
Number of Measurements, Maximum Value, Minimum Value, Average Value, Standard Deviation |
||||
Calibration Method |
Single Point, Two Point Calibration |
||||
Operating Temperature |
-10℃~+50℃, can reach -20℃ with special requirements |
||||
Automatic Shutdown |
Automatically shut down after 3 minutes of inactivity |
||||
Power Supply |
Two 1.5V AA batteries, with low voltage prompt when battery power is insufficient |
||||
Weight |
200g including batteries |
||||
Size |
149mm×73mm×32mm (H×W×D) |